|
Miltenyi Biotec
apc conjugated anti human cd133 1 ![]() Apc Conjugated Anti Human Cd133 1, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/CD133%2F1+Antibody%2C+anti-human/pmc03997403-1-3-7 Average 95 stars, based on 1 article reviews
apc conjugated anti human cd133 1 - by Bioz Stars,
2026-10
95/100 stars
|
Buy from Supplier |
|
Bio-Techne corporation
human cd133 apc-conjugated antibody ![]() Human Cd133 Apc Conjugated Antibody, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/Human+CD133+APC-conjugated+Antibody/bio-techne+corporation___fab11331a Average 94 stars, based on 1 article reviews
human cd133 apc-conjugated antibody - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
R&D Systems
cd133 ![]() Cd133, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/Human+CD133+APC-conjugated+Antibody/pmc02795856-39-19-20 Average 93 stars, based on 1 article reviews
cd133 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
rea820 ![]() Rea820, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/CD133%2F2+Antibody%2C+anti-human%2C+REAfinity/10__21203_slash_rs__3__rs___549885_slash_v1-587-9-10 Average 91 stars, based on 1 article reviews
rea820 - by Bioz Stars,
2026-10
91/100 stars
|
Buy from Supplier |
|
Becton Dickinson
anti-human cd133 apc antibody ![]() Anti Human Cd133 Apc Antibody, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/facsaria/pmc11160969-120-32-36 Average 90 stars, based on 1 article reviews
anti-human cd133 apc antibody - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
human recombinant monoclonal anti cd133 1 rea753 miltenyi biotec ![]() Human Recombinant Monoclonal Anti Cd133 1 Rea753 Miltenyi Biotec, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/CD44+Antibody%2C+anti-human%2C+REAfinity/pmc09477743__41590_2022_1290_MOESM1_ESM-97-115-120 Average 95 stars, based on 1 article reviews
human recombinant monoclonal anti cd133 1 rea753 miltenyi biotec - by Bioz Stars,
2026-10
95/100 stars
|
Buy from Supplier |
|
Revvity
anti cd133 apc ![]() Anti Cd133 Apc, supplied by Revvity, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/SureLight+Allophycocyanin-anti-6His+antibody%2C+lyophilized/pmc10296948-105-18-23 Average 97 stars, based on 1 article reviews
anti cd133 apc - by Bioz Stars,
2026-10
97/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
cd133 2 293c3 apc antibodies ![]() Cd133 2 293c3 Apc Antibodies, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/CD133%2F2+Antibody%2C+anti-human/us08357492-135-16-19 Average 95 stars, based on 1 article reviews
cd133 2 293c3 apc antibodies - by Bioz Stars,
2026-10
95/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
flow cd133 apc mouse miltenyi ![]() Flow Cd133 Apc Mouse Miltenyi, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/CD105+Antibody%2C+anti-mouse/pmc05727523__41598_2017_17884_MOESM1_ESM-35-81-84 Average 93 stars, based on 1 article reviews
flow cd133 apc mouse miltenyi - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Cell Signaling Technology Inc
apc labeled anti cd133 ![]() Apc Labeled Anti Cd133, supplied by Cell Signaling Technology Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/APC+Antibody/pmc09172155-71-6-9 Average 93 stars, based on 1 article reviews
apc labeled anti cd133 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Elabscience Biotechnology
anti human cd133 ![]() Anti Human Cd133, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/APC+Anti-Human+CD133+Antibody/pm41414814-45-17-20 Average 93 stars, based on 1 article reviews
anti human cd133 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
prominin apc ![]() Prominin Apc, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/cd133+1+apc/Prominin-1+Antibody%2C+anti-mouse/bio_rxiv__64898__2026__02__19__706795-246-33-37 Average 96 stars, based on 1 article reviews
prominin apc - by Bioz Stars,
2026-10
96/100 stars
|
Buy from Supplier |
Image Search Results
Journal: PLoS ONE
Article Title: Evaluation of Cancer Stem Cell Markers CD133, CD44, CD24: Association with AKT Isoforms and Radiation Resistance in Colon Cancer Cells
doi: 10.1371/journal.pone.0094621
Figure Lengend Snippet: Antibodies used for flow cytometry experiments.
Article Snippet: , PE or
Techniques: Flow Cytometry, Control
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Examination of the relationship between different circulating progenitor or mature endothelial cells and the risk of AD/dementia by using Cox proportional hazards regression models after adjusting for covariates
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Detailed examination of the relationship between CD34+CD133+ (log-transformed) and the risk of AD/dementia risk
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Characteristics of the study sample based on circulating CD34+CD133+ EPC quartiles
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Survival analyses of circulating CD34+CD133+ cells for AD risk. Circulating the proportions (%) of CD34+CD133+ EPCs were divided into four quartiles based on the cell numbers (Q1 = 0.002–0.021; Q2 = 0.021–0.033; Q3 = 0.033–0.050; and Q4 = 0.050–0.609). Kaplan-Meier survival analysis was conducted to evaluate the survival-free time before AD over 14 years of follow-up to examine the relationship between CD34+CD133+ quartiles and AD incidence for: (A) all of the participants; (B) and (C) stratified based on the genotypes, (B) kirre like nephrin family adhesion molecule 3 (KIRREL3) rs4144611 major homozygotes TT vs. GG + TG; (C) KIRREL3 rs580382 major homozygotes CC vs. TT + CT, and (D) exocyst complex component 6B (EXOC6B) rs61619102 major homozygotes CC vs. GG + GC. P values are shown for statistical significance. Q: quartile
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: The relationship between circulating CD34+CD133+ cells and reduced AD risk in the presence of vascular diseases. The FHS participants were stratified into divided based on the CD34+CD133+ EPC proportion quartiles and further divided into those individuals with the absence or presence of different vascular diseases. In the absence of any peripheral and central vascular diseases (A, B), in the presence of CHD (C, D), HTN (E, F), stroke (G, H), silent infarcts (I, J), CMBs (K, L), and high WMHI (M, N), the numbers and percentages of incident AD (A, C, E, G, I, K, and M) and all-cause dementia (B, D, F, H, J, L, and N) across four CD34+CD133+ quartiles were examined by using Chi-squared test with indicated P values. Q: quartile
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Comparisons of brain volumes across circulating CD34+CD133+ EPC quartiles
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: GWAS on the interactive effects of genetic factors and circulating CD34+CD133+ cells on AD risk. The FSH analytical pipeline was used to perform GWAS. The interaction between genome-wide SNP dosage and log-transformed proportions (%) of circulating CD34+CD133+ EPCs for AD risk was tested by using the GEEPACK model (logistic regression utilizing generalized estimating equations) adjusting for age, sex, years of education, and the first 10 PCs. As shown in the Manhattan plot, 8 SNPs showed significant interactions with CD34+CD133+ frequency on AD risk (A). Seven of the identified SNPs with a P value < 5.0 × 10 −8 originated from gene KIRREL3 on chromosome 11 (rs580382 and rs4144611 were selected for further analysis), and 1 of them originated from EXOC6B (chromosome 2, rs61619102). Only r 2 ≥ 0.1 and SNPs with MAF ≥ 10% were considered. Manhattan plot (A) was used for visualization to identify the genotypes of two genes ( KIRREL3 and EXOC6B ) that had interactive effects with CD34+CD133+ EPCs for AD risk. Gene structures, surrounding regions, and methylation sites of KIRREL3 (B) and EXOC6B (C) are presented by using LocusZoom
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques: Genome Wide, Transformation Assay, Methylation
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: Interactions between SNPs of KIRREL3 or EXOC6B and CD34+CD133+ on AD risk in FHS
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques:
Journal: Exploration of medicine
Article Title: The association between circulating CD34+CD133+ endothelial progenitor cells and reduced risk of Alzheimer’s disease in the Framingham Heart Study
doi: 10.37349/emed.2024.00216
Figure Lengend Snippet: The association between circulating CD34+CD133+ cells and the risk of AD in the context of genetic background
Article Snippet: Then, PBMCs were isolated via Ficoll (General Electric) gradient centrifugation, counted, incubated with FcR blocking antibodies (Miltenyi Biotec), labeled with anti-human KDR PE antibody (R&D Systems), anti-human CD34 FITC antibody (BD Biosciences),
Techniques: